â— Model NO.: EA8DC
â— High voltage rating: DC 250V~DC 1500V
â— Wide current Rating: 63-800A
â— Overload and short circuit protection
â— Full accessories
â— Application: Photovoltaic or other DC power system application
â— IEC60947-1, IEC60947-2
Â
Â
Â
The EA8DC series is a range of dedicated DC MCCBs (circuit breakers) designed specifically for use in DC power grid circuits. These circuit breakers are engineered to operate within a rated voltage range of DC 250V to DC 1500V and a rated working current range of 63A to 800A. They are primarily utilized for electrical distribution and protection in photovoltaic (PV) systems and other DC power applications.
Â
The EA8DC series circuit breakers offer comprehensive protection functions, including overload long delay and short-circuit instantaneous protection. These features ensure that the circuit breakers can effectively distribute electricity, safeguarding the integrity of electrical lines and protecting power equipment from overload, short circuits, and other potential fault hazards.
Â
In terms of standards compliance, the EA8PV series DC MCCBs adhere to the requirements outlined in IEC 60947-1 and GB/T14048.1 for general provisions. These standards define the general principles and guidelines for low-voltage switchgear and controlgear, ensuring the safety, performance, and reliability of electrical equipment. Additionally, the circuit breakers meet the specifications of IEC 60947-2 and GB/T14048.2, which specifically address the requirements for circuit breakers.
Â
By conforming to these international standards, the EA8DC series circuit breakers guarantee the quality, safety, and performance expected in DC power grid applications. They are engineered to provide reliable protection against various electrical faults, ensuring the smooth operation of PV systems and other DC installations.
Â
To summarize, the EA8DC series of photovoltaic dedicated DC MCCBs are specifically designed for use in DC power grid circuits. With a wide voltage and current range, these circuit breakers offer comprehensive protection functions to safeguard electrical lines and power equipment from overload, short circuits, and other fault hazards. Compliant with international standards such as IEC 60947-1, GB/T14048.1, IEC 60947-2, and GB/T14048.2, the EA8DC series circuit breakers ensure the quality, safety, and performance required for reliable operation in photovoltaic systems and other DC power applications.
Â
Â
Model NO. |
EA8DC |
||||
Specifications |
250 |
315 |
|||
Pole number |
2 Poles and 3 Poles |
||||
Rated current In (A) |
63, 80, 100, 125, 140, 160, 200, 225, 250 |
280, 300, 315 |
|||
Rated insulation voltage Ui (V) |
1500 |
||||
Rated impulse withstand voltage Uimp (V) |
12 |
||||
Application type |
DC |
PV |
DC |
PV |
|
Rated working voltage Ue (V) |
2P |
DC250, DC500V, DC750V, DC1000V, DC1500V |
|||
3P |
DC1000V, DC1250V, DC1500V |
||||
Rated short-circuit breaking capacity lcu (kA) |
2P |
DC1000V: 15 DC1500V: 5 |
DC250V, 500V: 50 DC750V, 1000V: 25 DC1500: 7.5 |
DC1000V: 15 DC1500V: 5 |
DC250V, 500V: 50 DC750V, 1000V: 25 DC1500: 7.5 |
3P |
DC1500V: 20 |
DC1000V, 1250V, 1500V: 25 |
DC1500V: 20 |
DC1000V, 1250V, 1500V: 25 |
|
Rated running short-circuit breaking capacity lcs (k A) Â |
2P |
=100% icu |
=100% icu |
||
3P |
=100% icu |
=100% icu |
|||
Wiring method |
2 Poles follows figure. 1 3 Poles follows figure. 2 |
||||
Isolating feaure |
yes |
yes |
|||
Selective category |
A |
A |
|||
Electrical life |
1500 |
1500 |
|||
Mechanical life |
20000 |
20000 |
|||
Arcing distance (mm) |
≤50 |
||||
Overall dimension (mm) (L×W×H) |
2P |
200*73*135 |
200*73*135 |
||
3P |
200*107*135 |
200*107*135 |
|||
Reference ambient temperature (℃) |
40 |
Â
Model NO. |
EA8DC |
||||||||||
Specifications |
400 |
630 |
800 |
||||||||
Pole number |
2 Poles and 3 Poles |
||||||||||
Rated current In (A) |
250, 315, 350, 400 |
400, 500, 630 |
630, 700, 800 |
||||||||
Rated insulation voltage Ui (V) |
1500 |
||||||||||
Rated impulse withstand voltage Uimp (V) |
12 |
||||||||||
Application type |
DC |
PV |
DC |
PV |
DC |
PV |
|||||
Rated working voltage Ue (V) |
2P |
DC1500V |
DC250, DC500V, DC750V, DC1000V, DC1500V |
||||||||
3P |
/ |
DC1000V, DC1500V |
|||||||||
Rated short-circuit breaking capacity lcu (kA) |
2P |
DC1000V: 30 DC1500V: 25 |
DC1000V: 40 DC1500: 30 |
DC250V, 500V: 25 DC750V, 1000V: 15 DC1500: 10 |
DC250V, 500V: 50 DC750V, 1000V: 25 DC1500: 10 |
DC250V, 500V: 25 DC750V, 1000V: 15 DC1500: 10 |
DC250V, 500V: 50 DC750V, 1000V: 25 DC1500: 10 |
||||
3P |
/ |
/ |
DC1000V: 30 DC1500V: 25 |
DC1000V: 40 DC1500V: 30 |
DC1000V: 30 DC1500V: 25 |
DC1000V: 40 DC1500V: 30 |
|||||
Rated running short-circuit breaking capacity lcs (k A) |
2P |
=100% icu |
=100% icu |
=100% icu |
|||||||
3P |
=100% icu |
=100% icu |
=100% icu |
||||||||
Wiring method |
2 Poles follows figure. 1 |
2 Poles follows figure. 1 3 Poles follows figure. 3 |
2 Poles follows figure. 1 3 Poles follows figure. 3 |
||||||||
Isolating feaure |
Yes |
Yes |
Yes |
||||||||
Selective category |
A |
A |
A |
||||||||
Electrical life |
1000 |
800 |
500 |
||||||||
Mechanical life |
20000 |
20000 |
 | ||||||||
Arcing distance (mm) |
≤100 |
||||||||||
Overall dimension (mm) (L×W×H) |
2P |
275*106*178 |
270*106*178 |
270*130*156 |
270*130*156 |
||||||
3P |
/ |
/ |
310*182*156 |
310*182*156 |
|||||||
Reference ambient temperature (℃) |
40 |
Â
Â
Â
Various characteristics and accessories of the circuit breaker shall be fixed by the WEAG and shall not be adjusted in the use. Under the compliance with custody and use conditions, from the date of 12 months from the WEAG delivery and in the situation of the circuit breaker intact seals, if the product is damaged or not used normally due to manufacturing quality problems, WEAG shall be responsible for replacement and repair without charge.
Â
Â
1. The elevation of the installation site shall not exceed 2000m.
2. The allowable ambient temperature shall not be higher than+50℃ and not lower than -5℃; (If the temperature exceeds+40℃ and the capacity is reduced, the specific situation must be negotiated with the manufacturer).
3. Atmospheric conditions: When the ambient temperature is 40℃, the relative humidity of the atmosphere shall not exceed 50%. Higher relative humidity is allowed at lower temperatures, such as 90% at 20℃, and condensation on the product surface due to temperature changes shall be taken into account.
4. The pollution level is Level 3.
5. Installation category is III.
6. The magnetic field at the installation position shall not exceed 5 times the geomagnetic field in any direction.
7. In a medium without explosion risk, and there is no gas or conductive dust in the medium that is sufficient to corrode metals and damage insulation.
8. In areas without wind and snow erosion.
9. Installation conditions:
a) Can be installed horizontally and vertically;
b) The installation site should have no significant impact or vibration, and should not be installed in flammable and explosive places.
Â
Â
Q: What is a DC MCCB?
Q: What is the purpose of the EA8DC DC MCCB?
Q: How does a DC MCCB differ from an AC MCCB?
Q: What are the key features of the EA8DC DC MCCB?
Q: Can the EA8DC DC MCCB be used in an AC electrical system?
Q: What are the applications of the EA8DC DC MCCB?
Q: How is the EA8DC DC MCCB installed and operated?
Q: What are the ratings and specifications to consider when selecting the EA8DC DC MCCB?
Â
http://www.weag-electric.com/